Removal
Bring a radiator frame into service situation.
Remove poliklinovy a belt.
Remove a damper of krutilny fluctuations. For this purpose fix a damper of krutilny fluctuations by means of a key for T10069 fixing.
To remove the oil pallet.
Turn off fastening of a sealing flange.
Remove the hermetic remains from sealing surfaces.
Installation
Remove the oil remains on a shatunny neck of a cranked shaft by means of pure rags.
Cut off a tube nouse on a forward mark (to opening O about 3 mm).
Put a hermetic layer in thickness about 2-3 mm, as is shown in
drawing 2.50
, on a pure sealing surface of a flange.
NOTE
Before drawing of hermetic cover an epiploon with pure rags.
The layer of hermetic should be not thicker than 2-3 mm, otherwise superfluous hermetic can get to the oil pallet and litter the mesh filter in a maslozaborny branch pipe.
Observe a hermetic expiration date.
The sealing flange should be established during 5 mines after drawing of silicone hermetic.
|
Establish directing T10215/1 plug 1 in front on a crankshaft 3 neck.
|
Fig. 2.51
. Installation of a sealing flange with an epiploon
|
Then accurately establish a sealing flange with an epiploon 2-via directing plug
(fig. 2.51)
.
Fasten a flange to the block of cylinders.
Establish the oil pallet.
NOTE
It is necessary to replace a fixing bolt of a damper of krutilny fluctuations.
|
Tighten a fixing bolt by means of a dinamometrichesky key of V.A.G 1601.
Establish a damper of krutilny fluctuations and fix it T10069 countersupport.
Tighten a new fixing bolt the moment of 100 N · m + 1/4 turns (90 °).
Establish poliklinovy a belt.