VW Touareg repair+ 1. Operation and car maintenance + 2. Engine + 3. Transmission + 4. Running gear + 5. Steering mechanism + 6. Brake system - 7. Onboard electric equipment - General information Types of storage batteries Check of the storage battery Having added the distilled water Check of density of electrolit Check of tension of idling of joint stock bank Shutdown and joint stock bank connection, cars with one storage battery Shutdown and joint stock bank connection (cars with two storage batteries) Removal and installation of the joint stock bank, being under a driver's seat Removal and installation of the relay of shutdown of the storage battery + Generator and starter + Combination of devices + Forward screen wiper + Headlights + Tables + 8. Body + electric equipment Schemes |
Volkswagen Touareg / Touareg repair>> Onboard electric equipment>> General information>> Check of the storage battery
Visual check
Surely check before measurements an external condition, conclusions and reliability of fastening of the storage battery
Joint stock bank check with the indicator
The indicator signals about level of electrolit and degree of a charge of the storage battery.
Joint stock banks with the indicator are available in two options.
– the low-served;
– the unattended.
The indicator can be in various places on the storage battery.
Three various color indications are possible.
"Green" – the joint stock bank has a sufficient charge.
"Black" – by joint stock bank it is partially discharged, charge level <65 % or it is discharged.
Colourless or yellow – it is necessary for joint stock bank replace.
Check of low-served joint stock banks
Given to joint stock bank is "low-served", that is it is required check level of electrolit and if necessary add the distilled water.
Check of level of electrolit
Check electrolit level on min/max labels on the joint stock bank case
(fig. 7.1)
.
Electrolit level in norm, it coincides with well-aimed max.
If level of electrolit is lower than a label – add the distilled water.
Check of level of electrolit in banks
Switch off ignition and all electric consumers.
At existence – remove a protective film from jams a banok.
Turn out jams a banok.
Check electrolit level in joint stock bank banks.
Level in norm if it is at level of a plastic crossing point
(fig. 7.2)
.
If electrolit level in norm, check jams and sealing rings of round section on existence of damages.
Replace the damaged parts.
Close banks jams.
If level of electrolit is lower than a maximum label, add the distilled water.
|
< |