VW Touareg repair+ 1. Operation and car maintenance + 2. Engine + 3. Transmission + 4. Running gear + 5. Steering mechanism + 6. Brake system - 7. Onboard electric equipment - General information Types of storage batteries Check of the storage battery Having added the distilled water Check of density of electrolit Check of tension of idling of joint stock bank Shutdown and joint stock bank connection, cars with one storage battery Shutdown and joint stock bank connection (cars with two storage batteries) Removal and installation of the joint stock bank, being under a driver's seat Removal and installation of the relay of shutdown of the storage battery + Generator and starter + Combination of devices + Forward screen wiper + Headlights + Tables + 8. Body + electric equipment Schemes |
Volkswagen Touareg / Touareg repair>> Onboard electric equipment>> General information>> Having added the distilled water
Check electrolit level in joint stock bank.
Switch off ignition and all electric consumers.
At existence – remove a protective film from jams a banok.
Turn out jams a banok.
Add the distilled water by means of the adaptation for filling of JSB VAS 5045. When filling to a maximum level supply of the distilled water automatically stops.
Check jams and sealing rings of round section on existence of damages. Replace the damaged parts.
Close banks jams.
Check tension of idling of joint stock bank
Make a trial trip
|
< |