   - General information
      Types of storage batteries
      Check of the storage battery
      Having added the distilled water
      Check of density of electrolit
      Check of tension of idling of joint stock bank
      Shutdown and joint stock bank connection, cars with one storage battery
      Shutdown and joint stock bank connection (cars with two storage batteries)
      Removal and installation of the joint stock bank, being under a driver's seat
      Removal and installation of the relay of shutdown of the storage battery
   + Generator and starter
   + Combination of devices
   + Forward screen wiper
   + Headlights
   + Tables
+ 8. Body
+ electric equipment Schemes



Volkswagen Touareg / Touareg repair>> Onboard electric equipment>> General information>> Check of tension of idling of joint stock bank
Check of tension of idling of joint stock bank is necessary for determination of its capacity.

NOTE
Before check the storage battery at least for 2 h cannot neither be discharged, nor to charge. The charge or the joint stock bank category during this period lead to inexact results of measurement.

Switch off ignition and all electric consumers, take the ignition key.
Remove the minus plug from joint stock bank
Wait for at least 2 h. At this time the storage battery cannot be discharged and charged.
Measure tension of idling of joint stock bank by means of a manual multimeter of V.A.G 1526 B.


If by results of measurements of tension of idling the joint stock bank charge was carried out, execute the actions given below.
Wait for at least 2 h. At this time the storage battery cannot be discharged and charged.
Measure tension of idling of joint stock bank by means of a manual multimeter of V.A.G 1526 B.
If tension of idling of joint stock bank after a charge less than 12,5 In, replace joint stock bank.


<