VW Touareg repair


+ 1. Operation and car maintenance
+ 2. Engine
+ 3. Transmission
+ 4. Running gear
+ 5. Steering mechanism
+ 6. Brake system
- 7. Onboard electric equipment
   + General information
   - Generator and starter
      Removal and starter installation (6-цил. the engine with injection of 3,2 l and the engine of 3,6 l of FSI, AKPP)
      Removal and starter installation (8-цил. the engine with injection of 4,2 l, AKPP)
      Removal and starter installation, 10-tsil. TDI engine of 4,9 l, AKPP
      Three-phase generator
      Removal and installation of the three-phase generator, with air cooling, 6-цил. the engine with injection
      Removal and installation of the three-phase generator, 8-цил. the engine with injection
      Removal and installation of a regulator of tension
   + Combination of devices
   + Forward screen wiper
   + Headlights
   + Tables
+ 8. Body
+ electric equipment Schemes



Volkswagen Touareg / Touareg repair>> Onboard electric equipment>> Generator and starter>> Removal and installation of the three-phase generator, 8-цил. the engine with injection
Removal

Fig. 7.60 . Contour of a poliklinovy belt 8-цил. the engine with injection: 1–a pulley of klinoremenny transfer – the three-phase generator; 2–tension roller; 3–a pulley of klinoremenny transfer – a cranked shaft; 4–by-pass roller; 5–a pulley of klinoremenny transfer – the conditioner compressor; 6–a pulley of klinoremenny transfer – the krylchaty pump of the amplifier of the steering mechanism; 7–a poliklinovy driving belt – the three-phase generator, by-pass a roller, the conditioner compressor, the krylchaty pump of the amplifier of the steering mechanism, a cranked shaft, the pump of system of cooling and a tension roller


Remove the engine.

Fig. 7.61 . Weakening of a tension of a poliklinovy belt


Weaken a poliklinovy driving belt, having turned a tension element by means of a cap wrench of SW 19 (fig. 7.61) .
Fix a tension element by means of a lock pin of T10060 A.

Fig. 7.62 . Tip of a wire of DF


Disconnect the tip of a wire of DF (fig. 7.62) .

Fig. 7.63 . Protective cap


Remove a protective cap (fig. 7.63) .

Fig. 7.64 . Fastening of a wire of B +


Turn off B wire + from the generator (fig. 7.64) .

Fig. 7.65 . Holder of tubes of system of cooling


Unscrew a fixing bolt 1 and remove the holder of 2 tubes of system of cooling from the generator (fig. 7.65) .
Take tubes of system of cooling 3 of the generator.

Fig. 7.66 . Fixing bolts of M8х90 of the generator


Unscrew fixing bolts of M8х90 of the generator (fig. 7.66) .

Installation
Installation is carried out in return sequence, thus it is necessary to consider the following.
Tighten connections with the ordered moment of an inhaling.