NOTE
The Tiptronic-F189 switch – is built in a plait of wires of two electromagnets.
|
Removal
Remove the selector handle.
It is necessary to observe sequence of shutdown of joint stock bank surely.
Disconnect the mass plug from joint stock bank at the switched-off ignition.
Remove an overlay of the central console.
Unblock and disconnect shtekerny connection 1.
Unscrew a bolt 2 and remove the holder.
Take shtekerny connection 3 of the holder
(fig. 3.23)
.
Disconnect shtekerny connections from electromagnets.
Press the lock lever to the right and pull the switch up-forward from a gear shifting drive
(fig. 3.24)
.
Installation
Installation is carried out in return sequence. Thus it is necessary to consider the following.
|
Fig. 3.25
. Cables: 1–a plait of wires to an electromagnet of blocking of the N110 selector; 2–a plait of wires to an electromagnet of blocking of the selector in the situation "P" N380; 3–a plait of wires to the selector switch (the lever is blocked in the situation "P") F319
|
To lay cables 1–3 how it is shown in drawing
(fig. 3.25)
.
Establish shtekerny connection 3 in the holder.
Tighten a bolt 2.
Establish an overlay of the central console.
Connect joint stock bank.
Establish the selector handle.