VW Touareg repair


+ 1. Operation and car maintenance
+ 2. Engine
- 3. Transmission
   + 6-step automatic transmission 09D
   - Hydrotransformer check
      Liquid pumping from the hydrotransformer
      Hydrotransformer installation
      Repair of a drive of gear shifting
      Removal and installation of the handle of the selector
      Check and adjustment of draft of the selector
      Removal and installation of draft of the selector
      Removal and slip installation
      Removal and frame installation
      Removal and installation of an electromagnet of blocking of the N110 selector
      Removal and installation of the switch of the selector (the lever is blocked in the situation "P") F319
      Removal and installation of a drive of gear shifting
      Removal and transmission installation, cars with the diesel R5 engine
      Removal and transmission installation, cars with petrol V6 and V8 engines, turbodiesel engines V6 TDI, V10 TDI and the petrol W12 engine
      Inhaling moments
      Removal and installation of highways and ATF radiator
      Removal and installation of the control unit of an automatic transmission of J217
      Replacement of a sealing ring of a secondary shaft
      Removal and installation of the oil pallet
      Removal and installation of the mesh oil filter
      Removal and installation of the sensor of pressure for hydrosystem 1 in AKP G193 and the pressure sensor for hydrosystem 2 in AKP G194
      Removal and installation of a zolotnikovy box
      Removal, installation and adjustment of the multipurpose F125 switch
   + Mechanical transmission 08D and transfer case Е473
   + Driveshaft
   + Driving mechanism
   + Tables
+ 4. Running gear
+ 5. Steering mechanism
+ 6. Brake system
+ 7. Onboard electric equipment
+ 8. Body
+ electric equipment Schemes



Volkswagen Touareg / Touareg repair>> Transmission>> Hydrotransformer check>> Removal and installation of a drive of gear shifting
Removal
Remove the selector handle.
Pull draft up and switch the selector in the situation "S".
It is necessary to observe sequence of shutdown of joint stock bank surely.
Disconnect the mass plug from joint stock bank at the switched-off ignition.
Remove the central console.
Take a noise isolation from the central console.
Unblock and disconnect the tip 1.
Unscrew a bolt 2 and remove the holder.

Fig. 3.23 . Shtekernye connections and bolt


Take shtekerny connection 3 of the holder (fig. 3.23) .
Disconnect the tip 1.

Fig. 3.15 . Tip and slip clamps


Carefully disconnect clamps 2 at the left and to the right of a frame (fig. 3.15) .

Fig. 3.16 . Frame clamps


Pull clamps at the left and on the right outside and pull a frame up (fig. 3.16) .

Fig. 3.12 . A tightening of a tightening bolt by means of a nozzle


Unscrew tightening a bolt on draft of the selector by means of T40031 nozzle (fig. 3.12) .

Fig. 3.26 . Bolts of fastening of the holder


Unscrew bolts 1 and remove the forward holder 2 drives of switching (fig. 3.26) .
Remove the back holder of a drive of gear shifting.
Pull a gear shifting drive together with draft of the selector a little back.

Fig. 3.27 . Lock washer and draft of the selector


Remove a lock washer 2 from draft of the selector 1 and disconnect a gear shifting drive from draft of the selector (fig. 3.27) .

Installation
Installation is carried out in return sequence. Thus it is necessary to consider the following.
Establish draft of the selector 1 and fix by means of a new lock washer 2.
Fasten forward and back holders of a drive of gear shifting (fig. 3.27) .

Fig. 3.25 . Cables: 1–a plait of wires to an electromagnet of blocking of the N110 selector; 2–a plait of wires to an electromagnet of blocking of the selector in the situation "P" N380; 3–a plait of wires to the selector switch (the lever is blocked in the situation "P") F319


To lay cables 1–3 how it is shown in drawing (fig. 3.25) .
Establish shtekerny connection 3 in the holder.
Tighten a bolt 2.
Connect the tip 1 (fig. 3.23) .
Adjust draft of the selector
Establish the central console.
Connect joint stock bank.
Establish the selector handle



<