Carefully disconnect tips of the sensor of pressure for hydrosystem 1 in AKP G193 1 and the pressure sensor for hydrosystem 2 in AKP G194 2(fig. 3.73).
Unscrew both sensors.
Installation
Always replace sensors together.
Establish two new sensors and tighten with the moment of 5 N · m.
Connect tips of sensors 1 and 2 against the stop.
Tips should click.
Establish the mesh oil filter and the oil pallet.
After installation fill in ATF, then check ATF level, if necessary – add oil.